FedRAMP Controls / SC
SC-8 Transmission Confidentiality and Integrity
Family SC
Baselines moderate
Mapped KSIs 4
Control statement
Protect the {{ insert: param, sc-08_odp }} of transmitted information.
Guidance: For each instance of data in transit, confidentiality AND integrity should be through cryptography as specified in SC-8 (1), physical means as specified in SC-8 (5), or in combination.
For clarity, this control applies to all data in transit. Examples include the following data flows:
* Crossing the system boundary
* Between compute instances - including containers
* From a compute instance to storage
* Replication between availability zones
* Transmission of backups to storage
* From a load balancer to a compute instance
* Flows from management tools required for their work - e.g. log collection, scanning, etc.
The following applies only when choosing SC-8 (5) in lieu of SC-8 (1).
FedRAMP-Defined Assignment / Selection Parameters
SC-8 (5)-1 [a hardened or alarmed carrier Protective Distribution System (PDS) when outside of Controlled Access Area (CAA)]
SC-8 (5)-2 [prevent unauthorized disclosure of information AND detect changes to information]
Guidance: SC-8 (5) applies when physical protection has been selected as the method to protect confidentiality and integrity. For physical protection, data in transit must be in either a Controlled Access Area (CAA), or a Hardened or alarmed PDS.
Hardened or alarmed PDS: Shall be as defined in SECTION X - CATEGORY 2 PDS INSTALLATION GUIDANCE of CNSSI No.7003, titled PROTECTED DISTRIBUTION SYSTEMS (PDS). Per the CNSSI No. 7003 Section VIII, PDS must originate and terminate in a Controlled Access Area (CAA).
Controlled Access Area (CAA): Data will be considered physically protected, and in a CAA if it meets Section 2.3 of the DHS's Recommended Practice: Improving Industrial Control System Cybersecurity with Defense-in-Depth Strategies. CSPs can meet Section 2.3 of the DHS' recommended practice by satisfactory implementation of the following controls PE-2 (1), PE-2 (2), PE-2 (3), PE-3 (2), PE-3 (3), PE-6 (2), and PE-6 (3).
Note: When selecting SC-8 (5), the above SC-8(5), and the above referenced PE controls must be added to the SSP.
CNSSI No.7003 can be accessed here:
https://www.dcsa.mil/Portals/91/documents/ctp/nao/CNSSI_7003_PDS_September_2015.pdf
DHS Recommended Practice: Improving Industrial Control System Cybersecurity with Defense-in-Depth Strategies can be accessed here:
https://us-cert.cisa.gov/sites/default/files/FactSheets/NCCIC%20ICS_FactSheet_Defense_in_Depth_Strategies_S508C.pdf Parameter placeholders {{ insert: param, … }} reference FedRAMP-set values in the resolved profile. Full parameter map is
preserved in the catalog database.
Covered by these Key Security Indicators
| KSI | Title | Category |
|---|---|---|
| KSI-AFR-03 | Authorization Data Sharing Determine how authorization data will be shared with all necessary parties in alignment with the FedRAMP Authorization Data Sharing (ADS) process and persistently address all related requirements and recommendations. | Authorization by FedRAMP |
| KSI-CNA-02 | Attack Surface _Persistently_ ensure _machine-based_ _information resources_ have a minimal attack surface and that lateral movement is minimized if compromised. | Cloud Native Architecture |
| KSI-CNA-03 | Enforce Traffic Flow Use logical networking and related capabilities to enforce traffic flow controls. | Cloud Native Architecture |